👀 SAMPLE REPORT — this is an example of the professional Reisch measurement report you receive. Yours is built from professional measurements of YOUR property.
📐 Reisch Roof Measurement Report — ready to print
312 Sunset Road, Pompton Plains NJ 07444
(855) 734-7241 · reischroofing.com
NJ · NY · PA — Licensed & Insured

ROOF MEASUREMENT REPORT

PRECISION AERIAL TAKEOFF · PER-FACET MEASUREMENT & EDGE ANALYSIS
123 Sample Street, Pompton Plains, NJ 07444
Report RTR-20260730-1356 · Prepared July 30, 2026 · Confidence 85% (auto-measured)
Aerial view with roof outline
Aerial imagery: Esri World Imagery · roof outline approximate

Measurement Summary

Total Roof Area (sloped surface)2,755 sq ft
Total Squares27.6
Suggested Waste Factor×1.27 (27%)
Squares incl. Waste35.0
Predominant Pitch10/12
Roof Facets12
Ridges / Hips (combined)63 LF
Valleys40 LF

Report Details

Rakes83 LF ◆
Eaves139 LF ◆
Step / Wall Flashing25 LF
Imagery Date2023-09-03
Imagery QualityHIGH
Measurement Confidence85%
GAF Master Elite (top 2% nationwide) · CertainTeed ShingleMaster Pro · Owens Corning Preferred · IKO Certified · HAAG Certified Inspector · NJ HIC #13VH09822200
RTR-20260730-1356 · Prepared July 30, 2026Reisch Roofing and Construction LLC · (855) 734-7241 · reischroofing.comPage 1 of 5
Lengths Diagram
123 Sample Street, Pompton Plains, NJ 07444
RTR-20260730-1356
174838741184585228N20 ft
Facet layout is approximate (auto-measured from aerial imagery); lengths and areas are computed from the 3-D roof-plane model and verified on site before installation.
EavesRakesRidgesHipsValleysStep / Wall Flashing
ROOF-GEOMETRY ENGINE (85% confidence) — edge lengths computed from the building's reconstructed roof-line network (footprint straight-skeleton + roof-plane data), calibrated against 297 GAF professional aerial measurement ground-truth reports. Interior lines on the diagram are the engine's reconstruction.

Edge Totals

Eaves ◆139 LF
Rakes ◆83 LF
Ridges / Hips (combined)63 LF
Valleys40 LF
Step / Wall Flashing25 LF

Derived Material Lengths

Drip Edge (eaves + rakes)222 LF
Ridge Cap (ridges + hips)63 LF
Starter Strip (eaves)139 LF
Starter — GAF convention (eaves + rakes)222 LF
Leak Barrier — GAF (eaves + rakes + valleys + flash + hips)299 LF
Valley Lining (valleys)40 LF
Hip Count / Valley Count12 / 4
Edge lengths are measured along the slope (sloped length) for rakes, hips and valleys, and horizontally for eaves and ridges — the same convention used by industry aerial measurement reports.
◆ Measured from the building's public GIS footprint outline (OpenStreetMap / FEMA USA Structures) — perimeter-grade accuracy.
RTR-20260730-1356 · Prepared July 30, 2026Reisch Roofing and Construction LLC · (855) 734-7241 · reischroofing.comPage 2 of 5
Pitch Diagram
123 Sample Street, Pompton Plains, NJ 07444
RTR-20260730-1356
16/129/1216/1211/1210/1216/126/128/12N20 ft
Facet layout is approximate (auto-measured from aerial imagery); lengths and areas are computed from the 3-D roof-plane model and verified on site before installation.

Pitch Distribution

Pitch RangeAreaShare
Standard (5-7/12)412 sf15%
Moderate (8-10/12)1,330 sf48%
Steep (11+/12)1,013 sf37%

Pitch Notes

Predominant Pitch10/12
Steep Sections (11/12+)Yes — steep-slope labor applies
Each facet is labeled with its measured pitch (rise per 12" of run). Pitch is measured from aerial stereo imagery; on-site verification is performed before installation.
RTR-20260730-1356 · Prepared July 30, 2026Reisch Roofing and Construction LLC · (855) 734-7241 · reischroofing.comPage 3 of 5
Area Diagram
123 Sample Street, Pompton Plains, NJ 07444
RTR-20260730-1356
48 sf860 sf621 sf26 sf749 sf515 sf128 sf225 sfN20 ft
Facet layout is approximate (auto-measured from aerial imagery); lengths and areas are computed from the 3-D roof-plane model and verified on site before installation.

Per-Facet Detail

FacetPitchAzimuthPlan SFSloped SFSquares
F18/12217°3043733.73
F25/1237°2953203.20
F310/12210°2743523.51
F410/1235°2443113.11
F522/12†126°2184204.20
F68/12222°1431751.75
F79/1235°971201.20
F822/12†305°962302.30
F911/122°921271.27
F106/1294°83910.91
F1122/12305°651391.39
F1222/12†208°52980.98
TOTAL1,9632,75527.55
RTR-20260730-1356 · Prepared July 30, 2026Reisch Roofing and Construction LLC · (855) 734-7241 · reischroofing.comPage 4 of 5
Waste Calculation & Notes
123 Sample Street, Pompton Plains, NJ 07444
RTR-20260730-1356

Waste Calculation

Waste ScenarioTotal AreaSquares
Zero waste (measured)2,755 sf27.6
+4%2,865 sf28.7
+9%3,003 sf30.0
+14%3,140 sf31.4
+19%3,278 sf32.8
+27% — SUGGESTED (Reisch complexity tier)3,498 sf35.0
The suggested waste factor (×1.27) follows roof complexity — 12 hip(s) and 4 valley(s) detected. Simple gable roofs run 12%; cut-up roofs with multiple hips/valleys/dormers run up to 27%. Final material order is confirmed at contract.

How These Measurements Were Made

This report was produced by Reisch Roofing's aerial measurement system. Roof geometry is derived from high-resolution stereo aerial imagery: each roof plane (facet) is reconstructed individually with its own pitch, orientation and elevation, every edge is classified (eave, rake, ridge, hip, valley, wall flashing), and sloped lengths/areas are computed from the 3-D plane model — the same methodology used by industry-standard aerial takeoff reports. Eave and rake lengths were measured from the building's public GIS footprint outline (OpenStreetMap / FEMA USA Structures), giving perimeter-grade accuracy on those edges. Imagery date: 2023-09-03 (2.9 years old). † Small steep facets are displayed at the area-weighted pitch of their steep cluster — satellite stereo tends to over-read pitch on small steep planes; verified on site.

Measurement Confidence by Category

MeasurementConfidenceNotes
Total area / squaresHighDerived from the building outline; validated against professional aerial reports
Eaves (gutter lines)HighMeasured from the roof outline
Ridges & hipsModerate–HighComputed from the 3-D roof-plane model; unbiased on average
ValleysModerateMay under-read on roofs with dormers or porch roofs
Rakes (gable edges)IndicativeGable detection from overhead imagery is inherently limited — professional report or on-site verification recommended
Confidence tiers are derived from ongoing validation of this system against 500+ professional aerial-measurement reports on New Jersey homes. Where a category matters to your project (for example valley or gable work), Reisch verifies with a professional report or on-site measurement before contract.

Important Notes

1. Measurements are derived from aerial imagery and are intended for estimating purposes. Reisch Roofing verifies all critical dimensions on site before installation.
2. This is a measurement report only — it is not a quote, contract, or scope of work, and contains no pricing.
3. Concealed conditions (deck condition, layers, framing) cannot be determined from aerial imagery.
4. © 2026 Reisch Roofing and Construction LLC. Prepared for the property owner of record at the address above.
Reisch Roofing and Construction LLC
312 Sunset Road, Pompton Plains NJ 07444
Office (855) 734-7241 · Cell 908-229-5883
reischroofing@gmail.com · reischroofing.com
“There is no better way than the REISCH way!”
RTR-20260730-1356 · Prepared July 30, 2026Reisch Roofing and Construction LLC · (855) 734-7241 · reischroofing.comPage 5 of 5

Get yours

Order professional accurate measurements right from your Instant Quote: $99 roof · $90–$130 siding (by home size) · $149 roof + siding. Delivered in 1–2 business days — and the fee is credited toward your project if you hire Reisch. Even if you don’t go with us, you’ll own accurate verified measurements you can put in front of any contractor.

Get my instant quote →
Financing available: flexible monthly payments through Hearth, our financing partner — apply online in about 2 minutes at https://app.gethearth.com/partners/reisch-roofing-and-construction. Checking your options does not affect your credit.